Top Shelf Plumbing & Heating recently completed this Pennco 16 Series steam boiler replacement in Scranton, Pennsylvania. The installation was built around manufacturer-correct near-boiler piping, dependable condensate return, and the details an older one-pipe steam system needs to heat properly.

This project summary uses verified completed-work details while omitting the customer’s identity and exact address.

Replacing the boiler and deteriorated returns

The aging boiler was removed and replaced with a properly sized Pennco 16 Series steam boiler. Deteriorated wet-return piping was also replaced to restore a reliable path for condensate returning from the system.

Near-boiler piping built for dry steam

The new boiler was piped with dual boiler risers, a full-size black-steel header, a properly sized equalizer, and a Hartford Loop. This arrangement helps separate water from the steam before it enters the system mains, supporting quieter and more even distribution.

Venting, startup, and system balancing

Main vents and radiator air vents were upgraded where needed. After installation, the boiler was filled, fired, skimmed, tested, and balanced. Startup is a critical part of steam-boiler replacement because oils left from new piping can cause unstable water and wet steam.

Steam workmanship for Scranton homes

Steam heating is dependable when the boiler is sized to the connected radiation and the piping, venting, pressure controls, and returns work together. Top Shelf provides steam boiler installation, repair, and system corrections throughout Scranton and surrounding NEPA communities.

Installation photos

Front view of a new Pennco 16 Series steam boiler installed in Scranton
Dual boiler risers, full-size header, equalizer and Hartford Loop on a Pennco steam boiler
Controls, gauge glass, piping and vent connection on the completed Pennco steam boiler installation
Completed Pennco steam boiler replacement by Top Shelf Plumbing and Heating
RELATED LOCAL SERVICE

Steam Boiler Replacement Scranton, PA

Steam boiler replacement in Scranton, PA with connected-radiation sizing, manufacturer-correct near-boiler piping, low-pressure controls, skimming, and startup.

Frequently asked questions

Why are two boiler risers used on this Pennco installation?

Using both boiler outlets and the required full-size header helps reduce steam velocity and separate water before steam enters the system mains.

What does the Hartford Loop do?

The Hartford Loop connects the return near the boiler waterline and limits how much boiler water can be lost if a return pipe fails.

Why does a new steam boiler need to be skimmed?

Threading and assembly introduce oils that can make the boiler water surge and carry water into the steam piping. Skimming removes those surface oils.